logo
Guangdong Blue Whale Ultrasonic Equipment Co;Ltd 86--15007557067 michael@bwhalesonic.com
Mechanical Timer Dental Ultrasonic Cleaner 6.5L Stainless Steel 304 Tank

Mechanical Timer Dental Ultrasonic Cleaner 6.5L Stainless Steel 304 Tank

  • Highlight

    Mechanical Timer Dental Ultrasonic Cleaner

    ,

    6.5L Dental Ultrasonic Cleaner

    ,

    304 Tank Ultrasonic Instrument Cleaner Dental

  • Tank Size
    30x15x15cm
  • Unit Size
    32.5x18x28cm
  • Pack Size
    41x25.5x35.5cm
  • Ultrasonic Power
    150W
  • Heating Power
    300W
  • Timer
    0~30mins
  • Product Name
    Ultrasonic Bath
  • Feature
    Mechanical Control
  • Place of Origin
    China
  • Brand Name
    Whale Cleen
  • Certification
    CE
  • Model Number
    Z-031
  • Minimum Order Quantity
    2 Units
  • Price
    Negotiable
  • Packaging Details
    Carton Box Packing
  • Delivery Time
    Depend On Quantity
  • Payment Terms
    T/T
  • Supply Ability
    20000 Units Per Month

Mechanical Timer Dental Ultrasonic Cleaner 6.5L Stainless Steel 304 Tank

 

6.5L 150 Watt Ultrasonic Power Ultrasonic Dental Instrument Cleaner

 

How To Use Whale Cleen sonic Ultrasonic Dental Instrument Cleaner? 

 

First check the manufacturer’s instruction manual for ultrasonic cleaner maintenance information and recommended testing frequency. If manufacturer’s information is not available, the aluminum foil test, recommended on a monthly basis, is a fast and simple method to check the cleaning power of ultrasonic cleaning units.

Fill the ultrasonic tank with fresh cleaning solution and run the unit as usual. Lower a piece of aluminum foil into the operating tank vertically along the entire length of the tank until almost touching the bottom. Expose the foil to ultrasonic waves for 30 seconds.

Adequate functionality will result in uniform pitting and indentations on the foil. “Blind spots” or areas with no pitting indicates that the device is not cleaning uniformly and that service is needed.

 

Data Sheet Of Z-031:

 

Model Z-031(Mechanical Control)
Ultrasonic Frequency 40000Hz
Tank Material Stainless Steel 304
Tank Capacity 6.5L
Timer 1-30minutes ,Mechanical timer
Power Supply

Single Phase:

AC 100 ~ 120V, 50 / 60Hz
AC 220 ~ 240V, 50 / 60 Hz

Ultrasonic Power 150W
Heating Power 300 W , Mechanical Heating
Unit Size 300x150x150 mm ( L x W x H )
Tank Size 325x180x280 mm ( L x W x H )
Package Size 410x255x355 mm ( L x W x H )
N.W. 5.5 kg
G.W.

6.4 kg

 

 

If this model is not suitable for you, please check other in below chart.
 

Model Tank size Unit size Volume Actual ultrasonic power Rated ultrasonic power Ultrasonic frequency Heating power Timer Heating temperature
LxWxH(mm) LxWxH(mm) (L) (W) (W) (kHz) (W) (MIN) (℃)
Z-008 150x85x65 175x110x125 0.8 30 30 40 no 1-30 no
Z-01 150x135×100 175x160x210 2 50 60 40 150 1-30 0-80
Z-02 240x135x100 265x165x220 3.2 100 120 150
Z-03 300x150x100 325x180x225 4.5 150 180 300
Z-031 300x150x150 325x180x280 6.5 150 180 300
Z-04 300x240x150 325x265x280 10.8 200 240 450
Z-06 330x300x150 360x325x285 15 300 360 450
Z-08 500x300x150 530x325×285 22 400 480 600
Z-10 500x300x200 530x325x325 30 500 600 600
 

 

Customer's Cleaning Feedback:

 

Mechanical Timer Dental Ultrasonic Cleaner 6.5L Stainless Steel 304 Tank 0

 

Some Tips For Whale Cleen sonic Ultrasonic Dental Instrument Cleaner

  1. The unit should have the lid on the entire time it is running to limit aerosols and lower the noise level.

  2. Do not overfill the load with instruments as this will limit the cavitation process and make the unit less effective.

  3. A fresh solution should be used when the fluid becomes visibly cloudy, filled with debris, visibly dirty, or you are doing large amounts of instruments. The minimum is once a day. In busy practices, you may be changing the fluid multiple times a day.

  4. The type of fluid is as important as the amount of fluid. Do not use chlorides or corrosives. Stay with no-foam chemicals, or you will have a big mess! Do not use items that the manufacturer does not recommend. They may interfere with cavitation. Never run without fluid.

  5. Follow recommendations by instrument manufacturers as well as the recommendations for the ultrasonic unit when choosing the additive for the unit. Follow manufacturer's directions for use of both the fluid and the unit.

  6. Most manufacturers will tell you to degas the unit before adding instruments. This is the act of adding the solutions/water/tablet without the basket and allowing it to mix and "degas," or run the unit for five minutes and remove any other gasses before using.

  7. After the instruments have been through the ultrasonic bath, rinsing is recommended to remove any chemicals and residual debris.

  8. At the end of the day, empty all fluid from the unit and flush your entire unit with clear water. Allow to dry with the lid off over night.

  9. Do not set the unit in the sink to fill. This is an electrical item and should not be wet. Bring the water to the unit. Do cover vents or set on wet towel.

  10. Do not place items directly on the bottom of the unit with no basket. This can impact the transducers and limit the cavitation.